Shijiazhuang Fengyan Cable-To provide a complete solution for the use of cable products for various industries

  • Home

  • About Us

  • Product

  • Solution

  • News Center

  • Contact Us

MY mine mobile rubber sheathed cable
+
  • MY mine mobile rubber sheathed cable

MY mine mobile rubber sheathed cable

The insulation resistance between cable insulated main line cores and between main line core and ground wire shall not be less than 100MΩ · km when converted to 20 ℃. MT type cable has two structures of 4 cores and 5 cores, consisting of 3 main cores and a ground core (one core in the 5-core cable is a control line). The cable is twisted around the cushion core, and chlorinated polyethylene rubber sheath or black neoprene rubber sheath is extruded outside. Conductive core: soft copper wire, its performance in line with GB/T3956-1997.

E-mail:

  • Product Description

  • MY mine mobile rubber flexible cable
    Flexible rubber-sheathed cables for mining purposes
    Model (Type):MY Rated voltage (Rating Voltage):380/660V

    Nom.cross sectional areas mm2 Conductor structure NO./mm Insulation thickness mm Sheath thickness Sheath thickness mm Cable outer diameter Average diameter Cable approx. weight kg/km Maximum DC resistance of conductor (copper) Max.D.C. resistance(20 ℃ ) Ω /km 20 ℃ Current carring capacity(20 ℃ ) A
     Normianal mm Max mm
    3 × 4 1 × 4 56/0.30 1.4 3.5 20.9 23.0 637 4.950 35
    56/0.30 4.950
    3 × 6 1 × 6 84/0.30 1.4 3.5 22.9 25.1 856 3.300 46
    84/0.30 3.300
    3 × 10 1 × 10 84/0.40 1.6 4.0 27.8 30.6 1304 1.910 64
    84/0.40 1.910
    3 × 16 1 × 10 126/0.40 1.6 4.0 30.3 33.3 1545 1.210 85
    84/0.40 1.910
    3 × 25 1 × 16 196/0.40 1.8 4.5 36.4 40.1 2269 0.780 113
    126/0.40 1.210
    3 × 35 1 × 16 276/0.40 1.8 4.5 40.5 44.6 2786 0.554 138
    126/0.40 1.210
    3 × 50 1 × 16 396/0.40 2.0 5.0 45.5 50.1 3554 0.386 173
    126/0.40 1.210
    3 × 70 1 × 25 360/0.50 2.0 5.0 51.5 55.1 4587 0.272 215
    196/0.40 0.780


    Remarks:
    1. The insulation resistance between cable insulated main line cores and between main line cores and ground wires shall not be less than 100MΩ · km when converted to 20 ℃.
    2. Product standard: MT818.5-2009.
    3. MT cable has 4-core and 5-core structures, consisting of 3 main cores and a ground core (one core in the 5-core cable is a control line). The cable is twisted around the cushion core, and chlorinated polyethylene rubber sheath or black neoprene rubber sheath is extruded outside.
    4. Conductive core: soft copper wire is used, and its performance conforms to GB/T3956-1997.
    5, insulation: the use of GB7594.2-1987 XJ-00A type rubber.
    6. Line core identification: insulation color separation identification is adopted, and the main line core is red, green and white. Ground wire black.
    7. Cable formation: the main line core, ground wire and rubber pad core are twisted to the right to form a cable.
    8. Sheath: GB7594.7-1987 XH-03A rubber is adopted. The oxygen index of the sheath rubber shall be ≥ 40.
    The flame retardant performance of the finished cable meets the requirements of the MT386-1995.
    10. Cable mark: model, voltage, specification and manufacturer's name are printed on the surface of the cable.

recommend of similar products